MIL-PRF-19500/317R
4.3.1 Power burn-in conditions. Power burn-in conditions are as follows: VCE = 5 - 15 V dc, PD = 360 mW
(500 mW for U), TA = room ambient as defined in 4.5 of MIL-STD-750. With approval of the qualifying activity and
preparing activity, alternate burn-in criteria (hours, bias conditions, TJ, mounting conditions) may be used for JANTX
and JANTXV quality levels. A justification demonstrating equivalence is required. In addition, the manufacturing
site's burn-in data and performance history will be essential criteria for burn-in modification approval.
4.3.2. Screening (JANHC and JANKC). Screening of JANHC and JANKC die shall be in accordance with
appendix G of MIL-PRF-19500. Burn-in duration for the JANKC level follows JANS requirements; the JANHC follows
JANTX requirements.
4.3.3 Thermal impedance (ĆVBE measurements). The ĆVBE measurements shall be performed in accordance with
method 3131 of MIL-STD-750 using the guidelines in that method for determining VH, VCE, IM, IH, tH, tSW, and tMD. The
ĆVBE limit used in screen 3c of 4.3 herein and table I, subgroup 2 shall be set statistically by the supplier over several
die lots and submitted to the qualifying activity for approval. See table IV, group E, subgroup 4 and figures 9, 10, 11,
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500, and as
specified herein. If alternate screening is being performed in accordance with MIL-PRF-19500, a sample of screened
devices shall be submitted to and pass the requirements of group A1 and A2 inspection only (table E-VIb, group B,
subgroup 1 is not required to be performed again if group B has already been satisfied in accordance with 4.4.2).
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500, and table I
herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E-VIa (JANS) of MIL-PRF-19500 and 4.4.2.1. Electrical measurements (end-
points) shall be in accordance with table I, subgroup 2. Delta requirements shall be in accordance with table II herein.
See 4.4.2.2 for JAN, JANTX, and JANTXV group B testing. Electrical measurements (end-points) for JAN, JANTX, and
JANTXV shall be after each step in 4.4.2.2 and shall be in accordance with table I, subgroup 2 herein. Delta
measurements shall be in accordance with table III herein.
4.4.2.1 Group B inspection, table E-VIa (JANS) of MIL-PRF-19500.
Subgroup
Method Condition
B4
1037
B5
1027
Sample size in accordance with table E-VIa of MIL-PRF-19500, adjust TA to achieve
TJ = +275°C minimum. Option 2: 216 hrs min., sample size = 45, c = 0; adjust TA to achieve
TJ = +225°C minimum. (NOTE: If a failure occurs, resubmission shall be at the test
conditions of the original sample.)