MIL-PRF-19500/317R
4.4.3.2 Group C inspection, table E-VII (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
C2
2036
Test condition E; not applicable for U, UA, and UB devices.
C6
Not applicable.
4.4.3.3 Group C sample selection. Samples for subgroups in group C shall be chosen at random from any
inspection lot containing the intended package type and lead finish procured to the same specification which is
submitted to and passes group A tests for conformance inspection. When the final lead finish is solder or any plating
prone to oxidation at high temperature, the samples for C6 life test may be pulled prior to the application of final lead
finish. Testing of a subgroup using a single device type enclosed in the intended package type shall be considered
as complying with the requirements for that subgroup.
4.4.4 Group D inspection. Conformance inspection for hardness assured JANS, JANJ, and JANTXV types shall
include the group D tests specified in table II herein. These tests shall be performed as required in accordance with
MIL-PRF-19500 and method 1019 of MIL-STD-750, for total ionizing dose or method 1017 of MIL-STD-750 for
neutron fluence as applicable (see 6.2 herein), except group D, subgroup 2 may be performed separate from other
subgroups. Alternate package options may also be substituted for the testing provided there is no adverse effect to
the fluence profile.
4.4.5 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table E-IX of MIL-PRF-19500 and as specified in table IV herein. Electrical
measurements (end-points) shall be in accordance with table I, subgroup 2. Delta requirements shall be in
accordance with table III herein.
4.5 Methods of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Pulse measurements. Conditions for pulse measurement shall be as specified in section 4 of
MIL-STD-750.
4.5.2 Input capacitance. This test shall be conducted in accordance with method 3240 of MIL-STD-750, except
the output capacitor shall be omitted.