MIL-PRF-19500/343K
TABLE II. Group D inspection.
Inspection 1/ 2/ 3/
MIL-STD-750
Limit
Unit
Method
Conditions
Symbol
Min
Max
Subgroup 1 4/
Neutron irradiation
1017
Neutron exposure VCES = 0 V
Breakdown voltage,
3011
15
V dc
Bias condition D; IC = 3 mA dc
V(BR)CEO
collector to emitter
Collector to base cutoff current
3036
Bias condition D;
20
nA dc
ICBO1
VCB = 15 V dc
µA dc
Collector to base cutoff current
3036
Bias condition D;
2
ICBO3
VCB = 30 V dc
µA dc
Emitter to base
3061
Bias condition D;
20
IEBO1
cutoff current
VEB = 3 V dc
Forward-current transfer ratio
3076
[15]
150
[hFE1]
VCE = 1 V dc;
IC = 3 mA dc
Collector-emitter saturation
3071
0.46
V dc
IC = 10 mA dc;
VCE(sat)
voltage
IB = 1 mA dc;
Base-emitter saturation voltage
3066
1.15
V dc
Test condition A; IC = 10 mA dc;
VBE(sat)
IB = 1 mA dc
Collector to emitter
3041
Bias condition C;
200
nA dc
ICES
cutoff current
VCE = 16 V dc
Subgroup 2
Total dose irradiation
1019
Gamma exposure VCES = 12 V
Condition A
Breakdown voltage,
3011
15
V dc
Bias condition D; IC = 3 mA dc
V(BR)CEO
collector to emitter
Collector to base cutoff current
3036
Bias condition D;
20
nA dc
ICBO1
VCB = 15 V dc
µA dc
Collector to base cutoff current
3036
Bias condition D;
2
ICBO3
VCB = 30 V dc
µA dc
Emitter to base
3061
Bias condition D
20
IEBO1
cutoff current
VEB = 3 V dc
Forward-current transfer ratio
3076
[15]
150
[hFE1]
VCE = 1 V dc;
IC = 3 mA dc
See footnotes at end of table.