MIL-PRF-19500/374E
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500, and table I
herein. Electrical measurements (end-points) shall be in accordance with the applicable inspections of table I, group
A, subgroup 2 herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in tables E-VIA (JANS) and E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500 and 4.4.2.1 and
4.4.2.2 herein. Electrical measurements (end-points) shall be in accordance with the applicable inspections of table I,
subgroup 2 herein. Delta measurements shall be in accordance with table II herein.
4.4.2.1 Group B inspection, table E-VIA (JANS) of MIL-PRF-19500.
Subgroup Method
Condition
VCE 10 V dc, 2,000 cycles.
B4
1037
VCE = 20 V dc 1.0 V dc; 96 hours. Adjusted as required by the chosen TA to give an
B5
1027
average lot TJ = +275C.
Load condition C (unclamped inductive) (see figure 6), TA = +25C
B7
3053
3C, duty cycle 10 percent; RS = 0.1.
Test 1 - tp = 640 s; RBB1 = 39; VBB1 = 20 V dc; RBB2 = ; VBB2 = 0;
VCC = 10 V dc; IC = 4.3 A dc; L = 1 mH (0.5, 5A) (Tower #7870 or equivalent).
Test 2 - tp = 2.88 mS; RBB1 = 120; VBB1 = 20 V dc; RBB2 = ; VBB2 = 0;
VCC = 10 V dc; IC = 1.4 A dc; L = 10 mH (0.11 , 12.5A) (Stancor C-2688 or equivalent).
B7
3053
Safe operating area (switching) (destructive); load condition B (clamped
inductive) TA = +25C; IB = 0.5 A dc, IC = 5 A dc; VCC = 55 V dc, L = 1.0 mH,
VBB2 = 3.0 V, RBB2 = 20 .
4.4.2.2 Group B inspection, table E-VIB (JAN, JANTX and JANTXV) of MIL-PRF-19500.
Subgroup Method
Condition
For solder die attach; VCE 10 V dc, 2,000 cycles.
B3
1037
For eutectic die attach TA = +35C max, PT adjusted to achieve TJ = +175C min,
B3
1027
VCE 10 V dc.
B5
Not applicable.
Load condition C (unclamped inductive) (see figure 6), TA = +25C, duty cycle
B7
3053
10 percent; RS = 0.1 .
Test 1 - tp = 640 s; RBB1 = 39; VBB1 = 20 V dc; RBB2 = ; VBB2 = 0; VCC = 10 V dc;
IC = 4.3 A dc; L = 1 mH (0.5 , 5A) (Tower #7870 or equivalent).
Test 2 - tp = 2.88 mS; RBB1 = 120; VBB1 = 20 V dc; RBB2 = ; VBB2 = 0; VCC = 10 V dc;
IC = 1.4 A dc; L = 10 mH (0.11 , 12.5A) (Stancor C-2688 or equivalent)
Safe operating area (switching) (destructive); load condition B (clamped inductive) TA = 25C;
B7
3053
IB = 0.5 A dc, IC = 5 A dc; VCC = 55 V dc, L = 1.0 mH, VBB2 = 3.0 V, RBB2 = 20 .
13