MIL-PRF-19500/408K
3. REQUIREMENTS
3.1 General. The individual item requirements shall be as specified in MILPRF19500 and as modified herein.
3.2 Qualification. Devices furnished under this specification shall be products that are manufactured by a
manufacturer authorized by the qualifying activity for listing on the applicable qualified manufacturer's list (QML)
before contract award (see 4.2 and 6.3)
3.3 Abbreviations, symbols, and definitions. Abbreviations, symbols, and definitions used herein shall be as
specified in MILPRF19500.
3.4 Interface and physical dimensions. The interface requirements and physical dimensions shall be as specified
in MILPRF19500 and on figure 1 (TO204AA, formerly TO3) herein.
3.4.1 Lead finish. Unless otherwise specified, lead finish shall be solderable in accordance with MILSTD750,
MILPRF19500, and herein. Where a choice of lead finish is desired, it shall be specified in the acquisition
document (see 6.2).
3.4.2 Polarity. The identification of terminals of the device package shall be as shown on figure 1. Terminal 1
shall be connected to the emitter, terminal 2 shall be connected to the base, and the collector shall be electrically
connected to the case.
3.5 Electrical performance characteristics. Unless otherwise specified herein, the electrical performance
3.6 Electrical test requirements. The electrical test requirements shall be as specified in table I.
3.7 Marking. Marking shall be in accordance with MILPRF19500.
3.8 Workmanship. Semiconductor devices shall be processed in such a manner as to be uniform in quality and
shall be free from other defects that will affect life, serviceability, or appearance.
4. VERIFICATION
4.1 Classification of inspections. The inspection requirements specified herein are classified as follows:
a.
Qualification inspection (see 4.2).
Screening (see 4.3).
b.
c.
4.2 Qualification inspection. Qualification inspection shall be in accordance with MILPRF19500 and as specified
herein.
4.2.1 Group E qualification. Group E inspection shall be performed for qualification or re-qualification only. In
case qualification was awarded to a prior revision of the specification sheet that did not request the performance of
table II tests, the tests specified in table II herein that were not performed in the prior revision shall be performed on
the first inspection lot of this revision to maintain qualification.