MIL-PRF-19500/485N
TABLE II. Group D inspection.
Inspection 1/ 2/ 3/
MIL-STD-750
Symbol
Limits
Unit
Min
Max
Method
Conditions
Subgroup 1 4/
Neutron irradiation
1017
Neutron exposure Vces = 0 V
µA dc
Collector to emitter cutoff current
3041
Bias condition D
100
ICE01
2N5415, S, UA, U4
VCE = 150 V dc
2N5416, S, UA, U4
VCE = 250 V dc
Collector to emitter cutoff current
3041
Bias condition D
2
mA dc
ICE02
2N5415, S, UA, U4
VCE = 200 V dc
2N5416, S, UA, U4
VCE = 300 V dc
µA dc
Collector to emitter cutoff current
3041
100
Bias condition D, VBE = 1.5 V dc
ICEX
2N5415, S, UA, U4
VCE = 200 V dc
2N5416, S, UA, U4
VCE = 300 V dc
µA dc
Emitter to base cutoff current
3061
IEBO
40
Bias condition D, VEB = 6 V dc
µA dc
Collector to base cutoff current
3036
100
Bias condition D
ICBO1
2N5415, S, UA, U4
VCB = 175 V dc
2N5416, S, UA, U4
VCB = 280 V dc
Collector to base cutoff current
3036
1
mA dc
Bias condition D
ICBO2
2N5415, S, UA, U4
VCB = 200 V dc
2N5416, S, UA, U4
VCB = 350 V dc
Forward-current transfer ratio
3076
[15]
120
VCE = 10 V dc, IC = 50 mA dc,
[hFE1] 5/
pulsed (see 4.5.1)
Forward-current transfer ratio
3076
[7.5]
VCE = 10 V dc,
[hFE2 ] 5/
Collector to emitter voltage
3071
2.3
V dc
IC = 50 mA dc, IB = 5 mA dc, pulsed
VCE(sat)
(saturated)
(see 4.5.1)
Base emitter voltage saturation
3066
1.73
V dc
Test condition B, VCE = 10 V dc,
VBE
See footnotes at end of table.