MIL-PRF-19500/509D
* TABLE I. Group A inspection - Continued.
MIL-STD-750
Limits
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 2 - Continued
VCE = 2 V dc; IC = 25 A dc;
hFE3
12
3076
Forward-current
pulsed (see 4.5.1)
transfer ratio
Subgroup 3 2/
TA = +150°C
High temperature operation:
ICEX2
3041
Collector to emitter
Bias condition A, VBE = -1.5 V dc
cutoff current
mA dc
1.0
VCE = 100 V dc
2N6338
mA dc
1.0
VCE = 150 V dc
2N6341
Low temperature
TA = -55°C
operation:
hFE4
10
VCE = 2.0 V dc; IC = 10 A dc;
Forward-current
3076
pulsed (see 4.5.1)
transfer ratio
Subgroup 4
3251
Pulse response
Test condition A, except test
circuit and pulse requirements in
accordance with figure 2.
µs
Turn-on time
0.5
VCC ≈ 80 V; IC = 10 A dc
ton
IB1 = 1.0 A dc
µs
Turn-off time
1.25
VCC ≈ 80 V; IC = 10 A dc
toff
IB1 = IB2 = 1.0 A dc
µs
1.0
Storage time
VCC ≈ 80 V; IC = 10 A dc
ts
IB1 = IB2 = 1.0 A dc
Magnitude of common
3306
4.0
12
VCE = 10 V dc; IC = 1.0 A dc;
|hFE|
emitter, small-signal
f = 10 MHz
short-circuit, forward-
current transfer ratio
Open capacitance
3236
450
pF
VCB = 10 V dc; IE = 0;
Cobo
open circuit
0.1 MHz ≤ f ≤ 1 MHz
See footnotes at end of table.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.