MIL-PRF-19500/515D
* TABLE II. Groups B, C, and E delta and electrical measurements. 1/ 2/ 3/ 4/ 5/
Steps
Inspection
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
ĆICEX1
100 percent of
1.
Collector to
3041
Bias condition A; VBE = +1.5 V
initial value or 2
emitter cutoff
dc
µA, whichever
current
is greater.
VCE = 120 V dc
2N6378
VCE = 140 V dc
2N6379
± 25 percent
ĆhFE2
2.
Forward - current
3076
VCE = 4 V dc; IC = 20 A dc;
transfer ratio
change from
pulsed (see 4.5.1)
initial reading.
± 50 mV change
ĆVCE(sat)1
3.
Collector to
3071
IC = 2.0 A dc; IB = 20 A dc,
emitter voltage
from previously
pulsed (see 4.5.1)
(saturated)
measured
value.
1/ See MIL-PRF-19500 for sampling plan.
2/ Devices which exceed the group A limits for this test shall not be acceptable.
3/ The delta measurements for table E-VIB (JAN, JANTX and JANTXV) of MIL-PRF-19500 are subgroup 6, see
able II herein, steps 1 and 2.
4/ The delta measurements for table E-VII of MIL-PRF-19500 are as follows:
a. Subgroup 2 and 3, see table II herein, step 1.
b. Subgroup 6, see table II herein, steps 2 and 3.
5/ The delta measurements for table E-IX of MIL-PRF-19500 are subgroups 1 and 2, see table II herein, all steps.