MIL-PRF-19500/516F
TABLE I. Group A inspection.
MIL-STD-750
Limit
Symbol
Unit
Inspection 1/
Method
Conditions
Min
Max
Subgroup 1
Visual and
2071
mechanical
examination
Subgroup 2 2/
µA dc
ID1
DC method, VR = VRWM
Column 5
Reverse current
4016
of table II
leakage
(column 4 of table II herein)
tp ≤ 300 ms, duty cycle ≤ 2 percent
V(BR)1
Breakdown voltage
4022
Column 2
V dc
of table II
I(BR) = column 3 of table II herein
Subgroup 3 2/
TA = +150°C
High temperature
operation
µA dc
ID2
DC method, VR = VRWM
Reverse current
4016
Column 9
leakage
of table II
(column 4 of table II herein)
Subgroup 4 2/
tp = 1 ms (see 4.5.3 and 4.5.4),
VC(MAX)
Column 6
V (pk)
Clamping voltage
of table II
maximum (pulsed)
Ip = column 7 of table II herein
Subgroups 5 and 6
Not applicable
1/ For sampling plan, see MIL-PRF-19500.
2/ All electrical testing shall be performed twice, once in each direction.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business