MILPRF19500/523D
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table EVII of MILPRF19500 and as follows. Electrical measurements (end-
points) shall be in accordance with table I, subgroup 2 herein.
Subgroup
Method
Conditions
C2
2036
Test condition A; weight = 10 pounds (4.54 Kg); time = 15 s.
C5
3131
Thermal resistance, see 4.3.1, RθJC(max) = 1.75°C/W.
Intermittent operation life, For solder die attach: VCB ≥ 10 V dc, 6,000 cycles,
C6
1037
TA ≤ +35°C.
Steady state life, For eutectic die attach: VCB ≥ 10 V dc, TA ≤ +35°C adjust PT to
C6
1026
achieve TJ = +150°C minimum.
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in appendix E, table EIX of MILPRF19500 and as specified in table II herein.
Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein.
4.5 Method of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Pulse response measurements. Conditions for pulse response measurement shall be as specified in section
4 of MILSTD750.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business