MIL�PRF�19500/523D
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E�VII of MIL�PRF�19500 and as follows. Electrical measurements (end-
Subgroup
Method
Conditions
C2
2036
Test condition A; weight = 10 pounds (4.54 Kg); time = 15 s.
C5
3131
Intermittent operation life, For solder die attach: VCB ≥ 10 V dc, 6,000 cycles,
C6
1037
TA ≤ +35�C.
Steady state life, For eutectic die attach: VCB ≥ 10 V dc, TA ≤ +35�C adjust PT to
C6
1026
achieve TJ = +150�C minimum.
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in appendix E, table E�IX of MIL�PRF�19500 and as specified in table II herein.
4.5 Method of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Pulse response measurements. Conditions for pulse response measurement shall be as specified in section
4 of MIL�STD�750.