MIL-PRF-19500/558J
4.4.2.3 Group B sample selection. Samples selected from group B inspection shall meet all of the following
requirements:
a. For JAN, JANTX and JANTXV samples shall be selected randomly from a minimum of three wafers (or from
each wafer in the lot) from each wafer lot. For JANS, samples shall be selected from each inspection lot.
See MIL-PRF-19500.
b. Shall be chosen from an inspection lot that has been submitted to and passed table I, subgroup 2,
conformance inspection. When the final lead finish is solder or any plating prone to oxidation at high
temperature, the samples for life test (subgroups B4 and B5 for JANS, and group B for JAN, JANTX, and
JANTXV) may be pulled prior to the application of final lead finish.
4.4.3 Group C inspection, Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VII of MIL-PRF-19500, and in 4.4.3.1 (JANS).and 4.4.3.2 (JAN, JANTX, and JANTXV) herein
for group C testing. Electrical measurements (end-points) and delta requirements shall be in accordance with table I,
subgroup 2 and 4.5.5 herein, delta parameters apply to subgroup C6.
4.4.3.1 Group C inspection, table E-VII (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
C2
2036
Test condition E, 3 ounce weight: Three bends of 15 degrees for 2N6988;
three bends of 90 degrees for 2N6987; not applicable to 2N6987U.
1,000 hours at VCB = 10 - 30 V dc; TJ = +150°C minimum. No heat sink or
C6
1026
forced-air cooling on device shall be permitted.
4.4.3.2 Group C inspection, table E-VII (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
C2
2036
Test condition E, 3 ounce weight: Three bends of 15 degrees for 2N6988;
three bends of 90 degrees for 2N6987; not applicable to 2N6987U.
RθJA, see 1.3.
C5
3131
C6
Not applicable.
4.4.3.3 Group C sample selection. Samples for subgroups in group C shall be chosen at random from any
inspection lot containing the intended package type and lead finish procured to the same specification which is
submitted to and passes group A tests for conformance inspection. Testing of a subgroup using a single device type
enclosed in the intended package type shall be considered as complying with the requirements for that subgroup.
* 4.4.4 Group D inspection. Conformance inspection for hardness assured JANS and JANTXV types shall include
the group D tests specified in table II herein. These tests shall be performed as required in accordance with
MIL-PRF-19500 and method 1019 of MIL-STD-750 for total ionizing dose or method 1017 of MIL-STD-750 for
neutron fluence, as applicable (see 6.2 herein), except group D, subgroup 2 may be performed separate from other
subgroups. Alternate package options may also be substituted for the testing provided there is no adverse affect to
the fluence profile.
4.4.5 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table E-IX of MIL-PRF-19500 and as specified in table III herein. Electrical
measurements (end-points) shall be in accordance with table I, subgroup 2 herein.
12