MIL-PRF-19500/627C
* TABLE I. Group A inspection.
Inspection
1/
Symbol
Limit
Unit
Method
Conditions
Min
Max
Subgroup 1
Visual and mechanical
2071
examination
Subgroup 2
°C/W
Thermal impedance
3101
See 4.3.1
ZθJX
Breakdown voltage
4022
VBR
V
300
1N6688, 1N6688US
400
1N6689, 1N6689US
Duty cycle ≤ 2 percent (pulsed) (see
Forward voltage
4011
V
VF1
0.90
IF = 5 A
0.97
VF2
IF = 20 A
1.2.
VF3
IF = 70 A
µA
Reverse current leakage
4016
IR1
50
(see 4.5.1)
Subgroup 3
TC = +100°C
High temperature
operation:
Reverse current leakage
4016
IR2
10
mA
(see 4.5.1)
TA = -65°C
Low temperature
operation:
Forward voltage
4011
VF4
1.0
V
Subgroup 4
Scope display
4023
Stable only. See 4.5.4, n = 116,
*
c=0
trr
40
ns
Reverse recovery time
4031
Condition B; IF = .5 A, IR = 1 A;
IRR = .25 A
Junction capacitance
4001
400
pF
VR = 10 V dc; f = 1 MHz;
CJ
VSIG = 50 mV (p-p) (maximum)
Subgroup 5
Not applicable
See footnote at end of table.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business