MIL-PRF-19500/628C
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500 and as
specified herein.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500 and table I
herein.
* 4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VIA (JANS) and E-VIB (JAN, JANTX and JANTXV) of MIL-PRF-19500 and 4.4.2.1 and
* 4.4.2.1 Group B inspection, table E-VIA (JANS) of MIL-PRF-19500. For B5, if a failure occurs, resubmission shall
be at the test conditions of the original sample.
Subgroup
Method
Condition
-0°C to +100°C, 25 cycles.
B3
1056
-55°C to +175°C, 100 cycles.
B3
1051
*
B3
4066
minute intervals, superimposed on IO = 0, VRWM = 0.
B4
1037
4.5.3); 2,000 cycles.
B5
1027
TJ = +150°C minimum. t = 1,000 hours. Temporary leads may be added
for surface mount devices. n = 45, c = 0. Delta shall not exceed 60 percent of
initial reading.
B6
4081
(maximum) ≤ 4°C/W; L = .375 inch (9.53 mm). For surface mount devices
(US version), RθJEC = 3.5°C/W maximum.
Peak reverse power, PRM ≥ 318 W for square wave in accordance with method
B8
4065
performed on each sublot; sampling plan n = 10, c = 0, end-points, see 4.4.2.
4.4.2.2 Group B inspection, table E-VIB (JAN, JANTX and JANTXV of MIL-PRF-19500.
Subgroup
Method
Condition
-0°C to +100°C, 10 cycles.
B2
1056
-55°C to +175°C, 25 cycles.
B2
1051
B3
1027
4.5.3.1). Delta shall not exceed 25 percent of initial reading.
6