MIL-PRF-19500/228R
4.5.3 Scope display evaluation. Scope display evaluation shall be sharp and stable in accordance with method
4023 of MIL-STD-750. Scope display may be performed on ATE (automatic test equipment) for screening only, with
the approval of the qualifying activity. Scope display in table I, subgroup 4 shall be performed on a curve tracer. The
reverse current (IBR) over the knee shall be 500 µA peak.
4.5.4 Thermal resistance. Thermal resistance measurement shall be performed in accordance with method 4081
of MIL-STD-750 using the guidelines in that method for determining IM, IH, and tH. Measurement delay time tMD =
70 µs max. Forced moving air or draft shall not be permitted across the devices during test.