MIL-PRF-19500/349J
* TABLE II. Group D inspection.
Inspection 1/ 2/ 3/
MIL-STD-750
Limit
Unit
Symbol
Method
Conditions
Min
Max
Subgroup 1 4/
Neutron irradiation
1017
Neutron exposure Vces = 0V
Bias condition D, IC = 100 µA dc
Breakdown voltage collector to
3001
V(BR)CBO
base
2N3506
60
V dc
2N3507
80
V dc
Bias condition D, IE = 10 µA dc
Breakdown voltage emitter to
3026
5
V dc
V(BR)EBO
base
Breakdown voltage collector to
3011
Bias condition D, IC = 10 mA dc,
V(BR)CEO
emitter
pulsed (see 4.5.1)
2N3506
40
V dc
2N3507
50
V dc
µA dc
Collector to emitter cutoff
3041
2
Bias condition A, VEB = 4 V dc
ICEX1
current
2N3506
VCE = 40 V dc
2N3507
VCE = 60 V dc
Forward-current transfer ratio
3076
VCE = 1 V dc, IC = 500 mA dc,
[hFE1] 5/
pulsed (see 4.5.1)
2N3506
[25]
250
2N3507
[17.5]
175
Forward-current transfer ratio
3076
VCE = 2 V dc, IC = 1.5 A dc, pulsed
[hFE2] 5/
(see 4.5.1)
2N3506
[20]
200
2N3507
[15]
150
Forward-current transfer ratio
3076
VCE = 3 V dc, IC = 2.5 A dc,
[hFE3] 5/
pulsed (see 4.5.1)
2N3506
[15]
2N3507
[12.5]
Forward-current transfer ratio
3076
VCE = 5 V dc, IC = 3.0 A dc,
[hFE4] 5/
pulsed (see 4.5.1)
2N3506
[12.5]
2N3507
[10]
Collector to emitter saturation
3071
0.575
V dc
*
VCE(sat)1
IC = 500 mA dc, IB = 50 mA dc,
voltage
pulsed (see 4.5.1)
Collector to emitter saturation
3071
1.15
V dc
IC = 1.5 A dc, IB = 150 mA dc,
VCE(sat)2
*
voltage
pulsed (see 4.5.1)
See footnotes at end of table.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business