MIL-PRF-19500/368M
TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limit
Unit
Method
Conditions
Min
Max
Subgroup 4
Pulse response:
3251
Test condition A
µs
Turn-on time
1
VCC = 200 V dc, IC = 20 mA dc,
ton
IB1 = 2 mA dc, see figure 14
µs
Turn-off time
10
VCC = 200 V dc, IC = 20 mA dc,
toff
IB1 = -IB2 = 2 mA dc, see figure 14
Magnitude of common- emitter
3306
3
15
VCE = 10 V dc, IC = 10 mA dc,
|hfe|
small-signal short-circuit forward-
f = 5 MHz
current transfer ratio
Open capacitance input open
3236
10
pF
VCB = 10 V dc, IE = 0,
Cobo
circuited
100 kHz ≤ f ≤ 1 MHz
Small-signal short- circuit forward-
3206
25
VCE = 10 V dc, IC = 5 mA,
hfe
current transfer ratio
f = 1 kHz
Input capacitance (output open
3240
75
pF
VCB = 5 V dc, IE = 0,
Cibo
circuited)
100 kHz ≤ f ≤ 1 MHz
Subgroup 5
(See figure 15) TC = +25°C,
3051
Safe operating area (continuous dc)
1 cycle, t = 1.0 s.
Test 1
VCE = 5 V dc, IC = 1 A dc
Test 2
Only 2N3439, 2N3439L, 2N3439UA
VCE = 350 V dc, IC = 14 mA dc
See footnotes at end of table.
15
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business