MIL-PRF-19500/402F
* TABLE II. Group E inspection (all quality levels) - for qualification and re-qualification only.
MIL-STD-750
Inspection
Sample
Method
Conditions
plan
45 devices
Subgroup 1
c=0
500 cycles.
1051
Temperature cycling
1071
Hermetic seal
Test conditions G or H.
Fine leak
Test conditions C or D.
Gross leak
See table I, subgroup 2.
Electrical measurements
Subgroup 2
45 devices
c=0
Condition A, 1,000 hrs.
1039
High temperature reverse
bias
See table I, subgroup 2.
Electrical measurements
Sample size
Subgroup 4
N/A
See MIL-PRF-19500.
Thermal impedance curves
3 devices
Subgroup 5
c=0
Condition B, VCBO = 325 V dc.
1001
Barometric pressure
Subgroup 8
45 devices
c=0
Reverse stability
1033
Condition B.