MIL-PRF-19500/415A
NOTES:
1. The input waveform is supplied by a pulse generator with the following characteristics:
pulse width = 20 µs, Zout = 50Ω, pulse repetition rate = 1 kHz, rise time ( tr ) and fall time (tf ) ≤ 10 ns,
duty cycle ≤ 2 percent.
2. The output waveform is monitored on a sampling oscilloscope with tf ≤ 15 ns, Rin ≥ 10 MΩ and CIN ≤ 11.5 pF.
FIGURE 2. Pulse response test circuit.
11