MIL-PRF-19500/448F
TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 2 - Continued
Forward-current transfer ratio
3076
100
300
VCE = 5 V dc; IC = 150 mA dc,
hFE3
pulsed (see 4.5.1)
Forward-current transfer ratio
3076
50
VCE = 5 V dc; IC = 500 mA dc;
hFE4
pulsed (see 4.5.1)
Collector-emitter saturated
3071
0.15
V dc
IC = 10 mA dc; IB = 1.0 mA dc;
VCE(SAT)1
voltage
pulsed (see 4.5.1)
Collector-emitter saturated
3071
0.20
V dc
IC = 150 mA dc; IB = 15 mA dc;
VCE(SAT)2
voltage
pulsed (see 4.5.1)
Collector-emitter saturated
3071
0.50
V dc
IC = 500 mA dc; IB = 50 mA dc;
VCE(SAT)3
voltage
pulsed (see 4.5.1)
Base-emitter non-saturated
3066
Test condition B; VCE = 5 V dc;
0.90
V dc
VBE
Base-emitter saturated
3066
0.80
V dc
Test condition A; IC = 10 mA dc;
VBE(SAT)1
voltage
Base-emitter saturated
3066
0.85
1.20
V dc
Test condition A; IC = 500 mA dc;
VBE(SAT)2
voltage
Subgroup 3
TA = +150°C
High-temperature operation
µA dc
Collector to base cutoff
3036
25
Bias condition D, VCB = 60 V dc
ICBO3
current
TA = -55°C
Low-temperature operation
Forward-current transfer ratio
3076
40
VCE = 5 V dc; IC = 150 mA dc
hFE5
pulsed (see 4.5.1)
See footnotes at end of table.