MIL-PRF-19500/452J
TABLE I. Group A inspection.
MIL-STD-750
Limits
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 1
Visual and mechanical
2071
examination
Subgroup 2 2/
Reference voltage
4022
See 4.5.3
VZ
6.08
6.72
IZ = 0.5 0.01 mA dc
1N4565 through 1N4569
V dc
IZ = 1.0 0.01 mA dc
1N4570 through 1N4574
V dc
IZ = 2.0 0.01 mA dc
1N4575 through 1N4579
V dc
IZ = 4.0 0.01 mA dc
1N4580 through 1N4584
V dc
4051
ZZ
ohms
Small signal breakdown
impedance
IZ = 0.5 0.01 mA dc,
200
1N4565 through 1N4569
Isig = 0.05 mA rms
IZ = 1.0 0.01 mA dc,
100
1N4570 through 1N4574
Isig = 0.1 mA rms
IZ = 2.0 0.01 mA dc,
1N4575 through 1N4579
50
Isig = 0.2 mA rms
IZ = 4.0 0.01 mA dc,
25
1N4580 through 1N4584
Isig = 0.4 mA rms
Subgroup 3
TA = -55C, 0C, +25C,
VZ
Voltage-temperature stability
(see 4.5.1 and 4.5.3)
+75C, +100C 2C,
IZ = column 4 of 1.4
1N4565A-1, 1N4565AUR-1
100
mV dc
1N4570A-1, 1N4570AUR-1
100
mV dc
1N4575A-1, 1N4575AUR-1
100
mV dc
1N4580A-1, 1N4580AUR-1
100
mV dc
1N4566A-1, 1N4566AUR-1
50
mV dc
1N4571A-1, 1N4571AUR-1
50
mV dc
1N4576A-1, 1N4576AUR-1
50
mV dc
1N4581A-1, 1N4581AUR-1
50
mV dc
See footnotes at end of table.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business