MIL-PRF-19500/455K
TABLE III. Group D inspection.
Inspection 1/ 2/ 3/
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 1
4/
1017
Neutron exposure, Vces = 0 V
Neutron irradiation
Breakdown voltage collector to
3011
Bias condition B; IC = 10 mA dc,
V(BR)CER
emitter
2N5664, 2N5666, 2N5666S
250
V dc
2N5665, 2N5667, 2N5667S
400
V dc
Bias condition D, IE = 10 µA dc,
Breakdown voltage emitter to
3026
6
V dc
V(BR)EBO
base
pulsed (see 4.5.1)
µA dc
Collector to emitter cutoff
3041
Bias condition C
0.4
ICES1
current
2N5664, 2N5666, 2N5666S
VCE = 200 V dc
2N5665, 2N5667, 2N5667S
VCE = 300 V dc
Collector to base cutoff current
3036
Bias condition D
ICBO
µA dc
2N5664, 2N5666, 2N5666S
0.2
VCB = 200 V dc
2N5664, 2N5666, 2N5666S
2.0
mA dc
VCB = 250 V dc
µA dc
2N5665, 2N5667, 2N5667S
0.2
VCB = 300 V dc
2N5665, 2N5667, 2N5667S
2.0
mA dc
VCB = 400 V dc
Forward-current transfer ratio
3076
VCE = 2 V dc, IC = 0.5 A dc
[hFE1] 5/
pulsed (see 4.5.1)
2N5664, 2N5666, 2N5666S
[20]
2N5665, 2N5667, 2N5667S
[12.5]
Forward-current transfer ratio
3076
VCE = 5 V dc, IC = 1.0 A dc
[hFE2] 5/
pulsed (see 4.5.1)
2N5664, 2N5666, 2N5666S
[20]
120
2N5665, 2N5667, 2N5667S
[12.5]
75
Forward-current transfer ratio
3076
VCE = 5 V dc, IC = 3.0 A dc
[hFE3] 5/
pulsed (see 4.5.1)
2N5664, 2N5666, 2N5666S
[7.5]
2N5665, 2N5667, 2N5667S
[5]
Forward-current transfer ratio
3076
2.5
VCE = 5 V dc, IC = 5 A dc,
[hFE4] 5/
pulsed (see 4.5.1)
Collector-emitter saturation
3071
0.46
V dc
IC = 3.0 A dc,
VCE(sat)1
voltage
2N5664, 2N5666, 2N5666S
2N5665, 2N5667, 2N5667S
See footnotes at end of table.