4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with table E-V of
MIL-PRF-19500 and table I herein. End-point electrical measurements shall be in accordance with table I,
subgroup 2.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E-VIA (JANS) and table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500
and 4.4.2.1 and 4.4.2.2 herein. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2.
Delta measurements shall be in accordance with the steps in table II herein as specified in the notes for table II.
4.4.2.1 Group B inspection, table E-VIA (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
VCB = 30 V dc minimum, TA = +25°C ±3°C; ton = toff = 3 minutes minimum.
B4
1037
No heat sink or forced-air cooling on the heating cycle shall be permitted.
See 4.5.3 herein.
B5
1027
4.4.2.2 Group B inspection, table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
TJ = +187.5°C ±12.5°C, VCE = 100 ±5 V dc; TA = ≤ +55°C. The applied PT minimum
B3
1027
of PT1 = 75 percent.
B5
3131
Not applicable.
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E-VII of MIL-PRF-19500 and herein. Electrical measurements (end-points)
shall be in accordance with table I, subgroup 2. Delta measurements shall be in accordance with the steps in table II
herein and as specified in the notes for table II.
Subgroup
Method
Condition
C2
2036
Terminal strength (tension) 2N5664 and 2N5665 only: Test condition A,
weight = 10 pounds, application time = 15 seconds.
Terminal strength (lead fatigue) 2N5666, 2N5666S, 2N5667, and 2N5667S
only: Test condition E (not applicable to 2N5666U3).
C5
3131
TJ = +187.5°C ±12.5°C, VCE = 100 ±5 V dc; TA = ≤ +55°C. The applied
C6
1026
PT minimum of PT1 = 75 percent.
4.4.4 Group D inspection. Conformance Inspection for hardness assured JANTXV, JANS, and JANKC types shall
include the group D tests specified in table III herein. These tests shall be performed as required in accordance with
MIL-PRF-19500 and method 1019 of MIL-STD-750, for total ionizing dose, or method 1017 of MIL-STD-750 for
neutron fluence, as applicable (see 6.2.e herein), except group D subgroup 2 may be performed separately from
other subgroups. Alternate package options may also be substituted for the testing provided there is no adverse
effect to the fluence profile.