MIL-PRF-19500/538G
*
4.3.4 Dielectric withstanding voltage.
a.
Magnitude of test voltage...................................900 V dc.
b.
Duration of application of test voltage....................15 seconds (min).
c.
Points of application of test voltage........................All leads to case (bunch connection).
d.
Method of connection.........................................Mechanical.
e.
Kilovolt-ampere rating of high voltage source..........1,200 V/1.0 mA (min).
f.
Maximum leakage current....................................1.0 mA.
g.
Voltage ramp up time...................................................500 V/second.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500, and as
specified herein.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500 and table I
herein. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VIA (JANS) and table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500 and herein.
Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein.
*
4.4.2.1 Group B inspection, table E-VIA (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
B3
2037
Test condition D, all internal leads for each device shall be pulled separately.
VCB ≥ 100 V dc.
*
B4
1037
VCB = 100 V dc; adjust TA and PD to achieve TJ = +275°C minimum.
B5
1027
PD = 100 percent of rated PT minimum; TA = +100°C maximum.
4.4.2.2 Group B inspection, table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
For eutectic die attach: VCB ≥ 100 V dc; adjust PT to achieve TJ =
B3
1027
+175°C minimum; TA = +30°C maximum
For solder die attach: 2,000 cycles, VCB ≥ 100 V dc.
B3
1037
10