MIL-PRF-19500/554E
4.3.1 Screening (JANHC). Screening of JANHC die shall be in accordance with MIL-PRF-19500.
4.3.2 Surge current. Surge current shall be performed in accordance with method 4066 of MIL-STD-750, with the
following conditions: IFSM = 1,000 A, 6 surges, tp = 8.3 ms, 1/2 sine wave, or rectangular pulse of equivalent IRMS,
IO = 0, VRWM = 0, duty factor one percent minimum, TA = 25°C.
* 4.3.3 Thermal impedance. The thermal impedance measurements shall be performed in accordance with method
3101 or 4081 as applicable of MIL-STD-750 using the guidelines in that method for determining IM, IH, tH, tSW (VC
and VH where appropriate). Measurement delay time (tMD) = 300 µs max. See table II, subgroup 4 herein.
* 4.3.4 Burn-in. Method 1038 of MIL-STD-750, test condition A. TJ = 150°C minimum, VR = 36V dc, IO = 0,
t = 48 hours.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500, and table I
herein.
* 4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VIb (JAN, JANTX, and JANTXV) of MIL-PRF-19500, and as follows. Electrical
measurements (end-points) shall be in accordance with table I, subgroup 2 herein.
Subgroup
Method
Condition
TJ = 150°C minimum, VR = 36 V dc. IO = 0, t = 48 hours.
B3
1048
B5
4081
See 4.3.3.
B7
4066
IFSM = 1,000 A (pk); VRM = 45 V (pk), IO = 45 A dc; 10 surges of 8.3 ms each at
1 minute intervals; 100°C < TC < 125°C; 22 devices, c = 0.
* 4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VII of MIL-PRF-19500, and as follows. Electrical measurements (end-points) shall be in
accordance with table I, subgroup 2 herein.
Subgroup
Method
Condition
C2
2036
Test condition A, 15 lbs, t = 15 s. Test condition F (method B), 15 pounds, t = 15 s.
Test condition D1, 3 inch-pound, t = 15 s. Test condition D2, 30 inch-pound, t = 15 s.
RΘJC = 1.0°C/W maximum in accordance with 4.3.3 except tH = 25 s (minimum),
C5
4081
n = 22, c = 0.
TJ = 150°C minimum, VR = 36 V dc. IO = 0.
C6
1048
Operational power cycling, IF = 50 A dc, TC (low) = +40°C +0°C, -15°C;
C6
1037
TC (high) = 115°C +5°C, -0°C; 6,000 cycles; 22 devices, c = 0, (see 4.5.5).
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with MIL-PRF-19500 and the
conditions for subgroup testing in table II herein. Electrical measurements (end-points) shall be in accordance with
table I, subgroup 2 herein.