MIL-PRF-19500/559K
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500, and
table I herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VIa (JANS) of MIL-PRF-19500 and 4.4.2.1. Electrical measurements (end-points) and
delta requirements shall be in accordance with table I, subgroup 2 and 4.5.5 herein. See 4.4.2.2 for JAN, JANTX,
and JANTXV group B testing. Electrical measurements (end-points) and delta requirements for JAN, JANTX, and
JANTXV shall be after each step in 4.4.2.2 and shall be in accordance with table I, subgroup 2 and 4.5.5 herein.
4.4.2.1 Group B inspection, table (JANS) E-VIa of MIL-PRF-19500.
Subgroup Method
Condition
VCB = 10 V dc, adjust device current, or power, to achieve a minimum ĆTJ of +100°C.
B4
1037
B5
1027
(NOTE: If a failure occurs, resubmission shall be at the test conditions of the original
sample.) VCB = 10 V dc, PD ≥ 100 percent of maximum rated PT (see 1.3).
Option 1: 96 hours minimum sample size in accordance with table E-VIa of
MIL-PRF-19500, adjust TA or PD to achieve TJ = +275°C minimum.
Option 2: 216 hours minimum, sample size = 45, c = 0; adjust TA or PD to achieve
TJ = +225°C minimum.
4.4.2.2 Group B inspection, (JAN, JANTX, and JANTXV). Separate samples may be used for each step. In the
event of a lot failure, the resubmission requirements of MIL-PRF-19500 shall apply. In addition, all catastrophic
failures during CI shall be analyzed to the extent possible to identify root cause and corrective action. Whenever a
failure is identified as wafer lot and wafer processing related, the entire wafer lot and related devices assembled from
the wafer lot shall be rejected unless an appropriate determined corrective action to eliminate the failure mode has
been implemented and the devices from the wafer lot are screened to eliminate the failure mode.
Step
Method
Condition
Steady-state life: 1,000 hours minimum, VCB = 10 V dc, power shall be applied to achieve
1
1026
TJ = +150°C minimum using a minimum of PD = 75 percent of maximum rated PT as defined
in 1.3. n = 45 devices, c = 0.
Blocking life, TA = +150°C, VCB = 80 percent of rated voltage,
2
1048
48 hours minimum. n = 45 devices, c = 0.
High-temperature life (non-operating), t = 340 hours, TA = +200°C. n = 22, c = 0.
3
1032
4.4.2.3 Group B sample selection. Samples selected from group B inspection shall meet all of the following
requirements:
a. For JAN, JANTX, and JANTXV samples shall be selected randomly from a minimum of three wafers (or
from each wafer in the lot) from each wafer lot. For JANS, samples shall be selected from each
inspection lot. See MIL-PRF-19500.
b. Shall be chosen from an inspection lot that has been submitted to and passed table I, subgroup 2,
conformance inspection. When the final lead finish is solder or any plating prone to oxidation at high
temperature, the samples for life test (subgroups B4 and B5 for JANS, and group B for JAN, JANTX,
and JANTXV) may be pulled prior to the application of final lead finish.