MILPRF19500/581C
TABLE I. Group A inspection.
Limit
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 1 2/
─┐
Visual and mechanical
2071
│
examination
│
│
Solderability 3/
2026
│
│
│
Resistance to solvents 3/ 4/
1022
├─ See MILPRF19500
│
Temperature cycling
1051
│
(air to air) 3/
│
│
Hermetic seal
1071
│
│
Fine leak
│
Gross leak
─┘
Electrical measurements
See subgroup 2 of this table
Precondition TA = +250°C at
Bond strength (destructive
2037
t = 24 hrs or TA = +300°C at
bond pull test) 3/
t = 2 hrs, n = 11 wires, c = 0
Subgroup 2
°C/W
Thermal impedance
3131
See 4.3.1
ZθJX
V(BR)CEO
Breakdown voltage,
3011
Bias condition D, pulsed (see 4.5.1)
Vdc
IC = 100 mA dc
collector to emitter
2N4237
50
2N4238
80
2N4239
100
Bias condition A, VBE = 1.5 V dc
ICEX1
Collector to emitter
3041
100
nA dc
cutoff current
VCE = 50 V dc
2N4237
VCE = 80 V dc
2N4238
VCE = 100 V dc
2N4239
ICBO
Collector to base
3036
Bias condition D
100
nA dc
cutoff current
VCB = 50 V dc
2N4237
VCB = 80 V dc
2N4238
VCB = 100 V dc
2N4239
Bias condition D, VBE = 6 V dc
IEBO
Emitter to base
3061
0.5
mA dc
cutoff current
See footnotes at end of table.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business