MIL-PRF-19500/585K
TABLE I. Group A inspection. Continued.
Symbol
Limit
Unit
Inspection
1/
MIL-STD-750
Method
Conditions
Min
Max
Subgroup 4
Forward recovery voltage
4026
IF = 0.5 A, tr = 12 ns
VFRM
V
1N6620, U, US
12
1N6621, U, US
12
1N6622, U, US
12
18
1N6623, U, US
18
1N6624, U, US
30
1N6625, U, US
Capacitance
4001
VR = 10 V, f = 0.1 to 1 MHz
CT
pF
1N6620, U, US
10
1N6621, U, US
10
1N6622, U, US
10
1N6623, U, US
10
1N6624, U, US
10
1N6625, U, US
10
Low current reverse
4031
Condition B. IF = 0.5 A,
trr1
ns
recovery time
IRM = 1.0 A
30
1N6620, U, US
30
1N6621, U, US
30
1N6622, U, US
1N6623, U, US
50
1N6624, U, US
50
1N6625, U, US
60
High current reverse
4031
Condition D. IF = 2A,
trr2
ns
di/dt = 100 A/s
recovery time
45
1N6620, U, US
45
1N6621, U, US
45
1N6622, U, US
60
1N6623, U, US
60
1N6624, U, US
80
1N6625, U, US
Peak recovery current
IRM(REC)
A
3.5
1N6620, U, US
3.5
1N6621, U, US
3.5
1N6622, U, US
1N6623, U, US
4.2
1N6624, U, US
4.2
1N6625, U, US
5.0
Scope display
4023
Stable only. See 4.5.4, n = 116,
c=0
See footnote at end of table.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business