MIL-PRF-19500/612E
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500, and as
specified herein.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with table E-V of
MIL-PRF-19500, and table I herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in tables E-VIa (JANS) and E-VIb (JAN, JANTX, and JANTXV) of MIL-PRF-19500. Electrical
measurements (end points) shall be in accordance with table I, subgroup 2 herein except ZθJX shall be performed after
subgroup 2 and 3) only.
*
4.4.2.1 Group B inspection table E-VIa (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
B3
2037
Test condition D.
VCB = 10 V dc minimum.
*
B4
1037
B5
1027
See 4.5.2.
4.4.2.2 Group B inspection, table E-VIb (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
VCB = 10 V dc minimum, 2,000 cycles.
B3
1037
* 4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VII of MIL-PRF-19500. Electrical measurements (end points) shall be in accordance with
table I, subgroup 2 herein.
Subgroup
Method
Condition
Tension: test condition A; weight 10 pounds ±5 ounces; time 15 seconds.
C2
2036
Bend strength: test condition F; bending stress 2 pounds, time 15 seconds.
*
C5
3131
VCB = 10 V dc minimum, 6,000 cycles.
C6
1037
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-IX of MIL-PRF-19500 and as specified in table II herein. Electrical measurements (end-
points) shall be in accordance with table I, subgroup 2 herein.
6