MIL-PRF-19500/118L
* TABLE I. Group A inspection.
MIL-STD-750
Limits
Symbol
Unit
Inspection 1/ 2/
Method
Conditions
Min
Max
Subgroup 1
Visual and mechanical examination
2071
Subgroup 2
C /W
ZθJX
Thermal impedance
3101
See 4.3.2
70
VF1
.8
1.0
V pk
Forward voltage
4011
IF = 100 mA pk, tp = 8.5 ms,
max. duty cycle 2 percent,
(pulsed, see 4.5.2)
Reverse current
1N483B, 1N5194, 1N5194UR, 1N5194US
nA dc
IR1
25
DC method, VR = 70 V dc
4016
1N485B, 1N5195, 1N5195UR, 1N5195US
nA dc
25
DC method, VR = 180 V dc
1N486B, 1N5196, 1N5196UR, 1N5196US
nA dc
25
DC method, VR = 225 V dc
A dc
1N483B, 1N5194, 1N5194UR, 1N5194US
IR2
1
4016
DC method, VR = 80 V dc
A dc
1N485B, 1N5195, 1N5195UR, 1N5195US
1
DC method, VR = 200 V dc
A dc
1N486B, 1N5196, 1N5196UR, 1N5196US
1
DC method, VR = 250 V dc
Subgroup 3
TA = +150C
High temperature operation
Reverse current
4016
IR3
A dc
DC method, VR = 70 V dc
5
1N483B, 1N5194, 1N5194UR, 1N5194US
A dc
5
DC method, VR = 180 V dc
1N485B, 1N5195, 1N5195UR, 1N5195US
A dc
5
1N486B, 1N5196, 1N5196UR, 1N5196US
DC method, VR = 225 V dc
TA = -55C
Low temperature operation
IF = 100 mA pk, tp = 8.5 ms,
VF2
1.2
V pk
Forward voltage
4011
max. duty cycle 2 percent,
(pulsed, see 4.5.2)
Subgroup 4
Not applicable
Subgroup 5
Method 4023 of MIL-STD-750,
Scope display evaluation
4023
figures 4023-3, -7, -9, -10 only
Subgroup 6
Surge current
4066
Condition A, IO = 200 mA dc, 10
surges at one per minute;
*
tp =1/120 s, IFSM = 2 A (pk).
Electrical measurements
See table I, subgroup 2
1/ For sampling plan, see MIL-PRF-19500.
2/ Electrical characteristics for all surface mount versions are identical to the corresponding axial leaded versions
unless otherwise specified.
* TABLE I. Group A inspection - Continued.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business