MILPRF19500/124L
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table EVIa (JANS) and table EVIb (JAN, JANTX, and JANTXV), of MILPRF19500, and as
follows. Electrical measurements (end-points) and delta requirements shall be in accordance with the applicable
steps of table II herein.
4.4.2.1 Product quality level JANS (table EVIa of MILPRF19500).
Subgroup
Method
Condition
Dwell time = 10 ±1 s; immersion to cover flat portion of terminal only.
B2
2026
2,000 cycles. See 4.5.6 herein.
B4
1037
IZ = column 15 of table III herein for 96 hours, TA = +125°C or adjusted, as required,
B5
1027
to give an average lot TJ = +225°C.
Option 1 TJ = +200°C, 336 hours.
Option 2 TJ = +175°C, 1,000 hours.
RΘJC = 12°C/W maximum, TA = +25°C. For purposes of this test "junction to case"
B6
4081
shall be used in lieu of "junction to lead" and "RΘJC" shall be used in lieu of "RΘJL".
The case shall be the reference point for calculation of junction to case thermal
resistance (RΘJC). The mounting arrangement shall be with heat sink to case.
4.4.2.2 Product quality levels JAN, JANTX and JANTXV (table EVIb of MILPRF19500).
Subgroup
Method
Condition
B2
4066
IZSM = column 10 of table III herein.
B3
1027
IZ = column 15 of table III herein, adjust TA, mounting, or both, to achieve
TC = 150ºC ±5ºC.
2,000 cycles. See 4.5.6 herein (separate samples may be used).
B3
1037
RΘJC = 12°C/W maximum; TA = +25°C. For purposes of this test, "junction to case"
B5
4081
shall be used in lieu of "junction to lead" and "RΘJC" shall be used in lieu of
"RΘJL".The case shall be the reference point for calculation of junction to case
thermal resistance (RΘJC). The mounting arrangement shall be with heat sink to
case.
TA = +200°C.
B6
1032
5