MILPRF19500/124L
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table EVII of MILPRF19500 and as follows. Electrical measurements (end-points) and delta
requirements shall be in accordance with the applicable steps of table II herein.
Subgroup
Method
Condition
Tension: Test condition A; 20 pounds; t = 15 ±3 s.
C2
2036
Torque (terminal): Test condition D1; 10 inch-ounces; t = 15 ±3 s.
C2
2036
Torque (stud): Test condition D2; 15 inch-pounds; t = 30 ±3 s.
C2
2036
Bending stress: Test condition F; 3 pounds; t = 15 ±3 s, method B.
C2
2036
C6
1027
IZ = column 15 of table III herein, adjust TA, mounting, or both, to achieve
TC = 150ºC ±5ºC.
C6
1037
6,000 cycles. See 4.5.6 herein (separate samples may be used).
C8
4071
22 devices, c = 0, JAN, JANTX, and JANTXV levels only. Temperature coefficient of
breakdown voltage (see 4.5.3 and 4.5.4). IZ = column 5 of table III herein,
TA = +25°C; T2 = T1 + 100°C; each sublot; α Vz = percent/°C column14 of table III
herein. Voltage regulation (see 4.5.2) each sublot. Vz(reg) = V dc, column 9 of
table III herein.
4.5 Methods of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows:
4.5.1 Surge current IZSM. The currents specified in column 10 of table III herein shall be applied in the reverse
direction and shall be superimposed on the current (IZ = column 5 of table III herein) a total of five surges at 1-minute
intervals. Each individual surge shall be a one-half square wave pulse of 1/120-second duration or an equivalent
one-half sine wave with the same effective (rms) current.
4.5.2 Voltage regulation VZ(reg). A current at 10 percent of IZ (column 8 of table III herein) shall be maintained
until thermal equilibrium is obtained, and the VZ shall then be increased to a level of 50 percent of IZ (column 8 of
table III herein) and maintained at this level for a period of time until thermal equilibrium is obtained at which time the
voltage change shall not exceed column 9 of table III herein. During this test, the temperature shall be equal to
TA = +25°C.
4.5.3 Regulator voltage. The IZ test current (column 5 of table III herein) shall be applied until thermal equilibrium
is obtained prior to reading the regulator voltage. During this test, the temperature shall be equal to TA = +25°C
4.5.4 Temperature coefficient of regulator voltage (αVZ). The device shall be temperature stabilized with current
applied prior to reading regulator voltage at the specified case temperatures.
4.5.5 Inspection condition. Unless otherwise specified in MILPRF19500 or herein, all inspections shall be made
at temperature shall be equal to TA = +25°C.