4.3.2 Power burn-in conditions. Power burn-in conditions are as follows: VCB = 10 - 30 V dc. Power shall be
applied to achieve TJ = +135°C minimum using a minimum PD = 75 percent of PT maximum, TA ambient rated as
defined in 1.3. With approval of the qualifying activity and preparing activity, alternate burn-in criteria (hours, bias
conditions, TJ, and mounting conditions) for JANTX and JANTXV quality levels may be used. A justification
demonstrating equivalence is required. In addition, the manufacturing site's burn-in data and performance history will
be essential criteria for burn-in modification approval.
4.3.3 Thermal impedance measurements). The thermal impedance measurements shall be performed in
accordance with method 3131 of MIL-STD-750 using the guidelines in that method for determining IM, IH, tH, and tMD
(and VC where appropriate). The thermal impedance limit used in screen 3c of 4.3 herein and subgroup 2 of table I
shall comply with the thermal impedance graphs in figures 12, 13, 14, 15, and 16 (less than or equal to the curve
value at the same tH time) and shall be less than the process determined statistical maximum limit as outlined in
method 3131. See table III, subgroup 4 herein.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500, and as
specified herein. If alternate screening is being performed in accordance with MIL-PRF-19500, a sample of screened
devices shall be submitted to and pass the requirements of subgroups 1 and 2, of table I herein, inspection only
(table E-VIb, group B, subgroup 1 is not required to be performed again if group B has already been satisfied in
accordance with 4.4.2).
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500, and table I
herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VIa (JANS) of MIL-PRF-19500 and 4.4.2.1 herein. Electrical measurements (end-points)
and delta requirements shall be in accordance with table I, subgroup 2 and 4.5.3 herein. See 4.4.2.2 herein for JAN,
JANTX, and JANTXV, group B testing. Electrical measurements (end-points) and delta requirements for JAN,
JANTX, and JANTXV, shall be after each step in 4.4.2.2 and shall be in accordance with table I, subgroup 2 and
4.5.3 herein.
4.4.2.1 Group B inspection, table E-VIa (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
VCB = 10 - 30 V dc. Adjust device current, or power, to achieve a minimum ĆTJ of 100°C.
B4
1037
B5
1027
occurs, resubmission shall be at the test conditions of the original sample.)
Option 1: 96 hours minimum sample size in accordance with MIL-PRF-19500,
table E-VIa, adjust TA or PD to achieve TJ = +275°C minimum.
Option 2: 216 hours minimum, sample size = 45, c = 0; adjusted TA or PD to achieve a
TJ = +225°C minimum.
B6
3131
12