MIL�PRF�19500/370H
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL�PRF�19500, and as
specified herein. If alternate screening is being performed in accordance with MIL�PRF�19500, a sample of
screened devices shall be submitted to and pass the requirements of table I, subgroup 1 and 2. Table E�VIB,
subgroup 1 of MIL�PRF�19500 is not required to be performed again if group B has already been satisfied in
accordance with 4.4.2.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with table E�V of
MIL�PRF�19500 and table I herein. Electrical measurements (end-points) shall be in accordance with the applicable
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the test methods and
conditions specified for subgroup testing in table E�VIB of MIL�PRF�19500 and as follows. Electrical measurements
(end-points) shall be in accordance with the applicable inspections of table I, subgroup 2 herein. Delta
measurements shall be in accordance with the applicable step of 4.6 herein.
Subgroup
Method
Conditions
For solder die attach: 2,000 cycles; VCB = 10 - 30 V dc, TA ≤ +35�C.
B3
1037
or
For eutectic die attach: VCB = 10 to 30 V dc, TA ≤ +35�C, adjust PT to achieve
1026
TJ = +175�C minimum.
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E�VII of MIL�PRF�19500 and as follows herein. Electrical measurements
(end-points) shall be in accordance with table I, subgroup 2 herein. Delta requirements shall be in accordance with
the applicable step of 4.6 herein.
Subgroup
Method
Conditions
C2
2036
Test condition A, weight = 10 pounds �10 ounce (4.5Kg �0.28Kg), t = 15 s.
C5
3131
For solder die attach: 6,000 cycles; VCB = 10 to 30 V dc, TA ≤ +35�C.
C6
1037
or
For eutectic die attach: VCB = 10 to 30 V dc, TA ≤ +35�C, adjust PT to achieve
1026
TJ = +175�C minimum.
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in appendix E, table E�IX of MIL�PRF�19500 and as specified in table II herein.
Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein. Delta requirements
shall be in accordance with the applicable step of 4.6 herein.
6