MIL-PRF-19500/435M
TABLE I. Group A inspection.
Inspection 1/
Symbol
Limits 2/
Unit
Method
Conditions
Min
Max
Subgroup 1
Visual and
2071
mechanical
examination
Subgroup 2
IF = 200 mA dc
VF
Forward voltage
4011
1.1
V dc
µA dc
IR1
Reverse current
4016
DC method; VR = column 6
Column 7
leakage
of table III
IZ = 250 µA dc (see 4.5.2)
VZ
Regulator voltage
4022
Column 2
Column 2
V dc
-VZ tol
+VZ tol
°C/W
ZθJX
Thermal impedance
3101
See 4.3.2
Subgroup 3
TA = +150°C
High-temperature
operation
µA dc
IR2
Reverse current
4016
DC method; VR = column 6
Column 3
of table III
Subgroup 4
IZ = 250 µA dc;
ZZT
Small-signal reverse
4051
Column 4
Ohms
breakdown
ISIG = 25 µA ac rms
impedance
IZ = 250 µA dc (see 4.5.5)
µV/√ Hz
Noise density
ND
Column 9
Subgroup 5
Not applicable
Subgroup 6
Surge current
4066
See 4.5.1
Electrical
Table I, subgroup 2
measurements
Subgroup 7
JANS only
IZ = 250 µA dc; T1 = +25°C,
αVZ
%/°C
Temperature
4071
Column 8
coefficient of
±5°C; T2 = T1 +100°C (see
regulator voltage
1/ For sampling plan, see MIL-PRF-19500.
2/ Column references are to table III herein.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business