MIL-PRF-19500/456E
* TABLE I. Group A inspection - Continued.
Unit
Symbol
Inspection 1/
MIL-STD-750
Limits
Min
Max
Method
Conditions
Subgroup 3
TA = +150C
High-temperature operation:
A dc
3041
Collector to emitter
50
ICEX2
Bias condition A;VBE = 1.5 V dc;
cutoff current
2N5302
VCE = 60 V dc
2N5303
VCE = 80 V dc
TA = -55C
Low-temperature operation:
3076
Forward current
hFE4
VCE = 2 V dc; pulsed (see 4.5.1);
transfer ratio
7
2N5302
IC = 15 A dc
7
2N5303
IC = 10 A dc
Subgroup 4
240
Small-signal short-circuit
3206
40
VCE = 10 V dc; IC = 1 A dc;
hfe
forward-current transfer ratio
f = 1 kHz
hfe
3306
2
40
Magnitude of small-signal
VCE = 10 V dc; IC = 1 A dc;
short-circuit forward-
f = 1 MHz
current transfer ratio
3236
Open circuit output
800
pF
VCB = 10 V dc; IE = 0;
Cobo
100 kHz < f 1 MHz
capacitance
Switching parameters:
s
See figure 2
0.2
Pulse delay time
td
s
Pulse rise time
See figure 2
0.9
tr
s
Pulse storage time
See figure 2
2.0
ts
s
Pulse fall time
See figure 2
1.0
tf
Subgroup 5
TC = 25C; power application
3051
Safe operating area
time 1 sec, 1 cycle
(continuous dc)
(see figures 3 and 4)
Test 1
2N5302
VCE = 6.67 V dc; IC = 30 A dc
2N5303
VCE = 10 V dc; IC = 20 A dc
See footnotes at end of table.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.