MIL-PRF-19500/477K
TABLE I. Group A inspection - Continued.
Inspection
1/
MIL-STD-750
Limit
Unit
Symbol
Method
Conditions
Min
Max
Subgroup 3 - continued
Duty cycle ≤ 2 percent (pulsed
Forward voltage
4011
1N5802, US, URS,
0.800
V
IFM = 1.0 A
VFM6
1N5804, US, URS,
1N5806, US, URS
1N5807, US, URS,
0.800
V
IFM = 4.0 A
VFM7
1N5809, US, URS,
1N5811, US, URS
TA = -65°C minimum.
Low-temperature
operation:
Duty cycle ≤ 2 percent (pulsed
Forward voltage
4011
VFM8
1N5802, US, URS,
1.075
V
IFM = 1.0 A
1N5804, US, URS,
1N5806, US, URS
1N5807, US, URS,
1.075
V
IFM = 4.0 A
1N5809, US, URS,
1N5811, US, URS
I(BR) = 100 µA dc
Breakdown voltage
4021
V(BR)2
1N5802, US, URS,
50
V dc
1N5807, US, URS
1N5804, US, URS,
100
V dc
1N5809, US, URS
1N5806, US, URS,
150
V dc
1N5811, US, URS
See footnotes at end of table.
15
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business