MIL�PRF�19500/539F
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E�VII of MIL�PRF�19500 and as follows. Electrical measurements (end-
Subgroup
Method
Conditions
C2
2036
Test condition A; weight = 10 pounds (4.54 Kg); time = 15 s.
C5
3131
VCE ≥ 10 V dc, 6,000 cycles, adjust device current, or power, to achieve a
C6
1037
minimum ĆTJ of +100�C.
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in appendix E, table E�IX of MIL�PRF�19500 and as specified in table II herein.
4.5 Method of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Pulse response measurements. The conditions for pulse response measurement shall be as specified in
7