4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table EVII of MILPRF19500 and as follows. Electrical measurements (end-
points) shall be in accordance with table I, subgroup 2 herein.
Subgroup
Method
Conditions
C2
2036
Test condition A; weight = 10 pounds (4.54 Kg); time = 15 s.
See 4.3.1, RθJC = 2.66°C/W.
C5
3131
VCE ≥ 10 V dc, 6,000 cycles, adjust device current, or power, to achieve a
C6
1037
minimum ĆTJ of +100°C.
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in appendix E, table EIX of MILPRF19500 and as specified in table II herein.
Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein.
4.5 Method of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Pulse response measurements. The conditions for pulse response measurement shall be as specified in
section 4 of MILSTD750.