MIL-PRF-19500/563G
* 4.3 Screening (JANS, JANTX, and JANTXV levels only). Screening shall be in accordance with table E-IV of
MIL-PRF-19500 and as specified herein. The following measurements shall be made in accordance with table I
herein. Devices that exceed the limits of table I herein shall not be acceptable.
Screen (see table E-IV
Measurement
of MIL-PRF-19500,)
(1) (2)
JANS level
JANTX and JANTXV levels
Gate stress test (see 4.3.2)
Gate stress test (see 4.3.2)
(3)
(3) (4)
optional
optional
Method 3161 of MIL-STD-750 (see 4.3.4)
Method 3161 of MIL-STD-750 (see 4.3.4)
(3) 3c
9
IGSSF1, IGSSR1, IDSS1, subgroup 2 of table 1
Subgroup 2 of table 1 herein
herein
10
Method 1042 of MIL-STD-750, test
Method 1042 of MIL-STD-750, test
condition B
condition B
11
IGSSF1, IGSSR1, IDSS1, rDS(on)1, VGS(th)1
IGSSF1, IGSSR1, IDSS1, rDS(on)1, VGS(th)1
subgroup 2 of table I herein;
subgroup 2 of table I herein
ĆIGSSF1 = ±20 nA dc or ±100 percent of
initial value, whichever is greater;
ĆIGSSR1 = ±20 nA dc or ±100 percent of
initial value, whichever is greater;
ĆIDSS1 = ±25 µA dc or ±100 percent of initial
value, whichever is greater
12
Method 1042 of MIL-STD-750, test
Method 1042 of MIL-STD-750, test
condition A, t = 240 hours
condition A
13
Subgroups 2 and 3 of table I herein;
Subgroup 2 of table I herein;
ĆIGSSF1 = ±20 nA dc or ±100 percent of
ĆIGSSF1 = ±20 nA dc or ±100 percent of initial
initial value, whichever is greater;
value, whichever is greater;
ĆIGSSR1 = ±20 nA dc or ±100 percent of
ĆIGSSR1 = ±20 nA dc or ±100 percent of initial
initial value, whichever is greater;
value, whichever is greater;
ĆIDSS1 = ±25 µA dc or ±100 percent of initial
ĆIDSS1 = ±25 µA dc or ±100 percent of initial
value, whichever is greater
value, whichever is greater
ĆrDS(on)1 = ±20 percent of initial value
ĆrDS(on)1 = ±20 percent of initial value
ĆVGS(th)1 = ±20 percent of initial value
ĆVGS(th)1 = ±20 percent of initial value
(1)
At the end of the test program, IGSSF1, IGSSR1, and IDSS1 are measured.
An out-of-family program to characterize IGSSF1, IGSSR1, IDSS1, and VGS(th)1 shall be invoked.
(2)
* (3)
Shall be performed anytime after temperature cycling, screen 3a. JANTX and JANTXV levels do not need to
be repeated in screening requirements.
(4)
This test need not be performed in group A when performed as a screen.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business