MIL-PRF-19500/570E
* 4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table E-VII of MIL-PRF-19500, and as follows. Electrical measurements (end-points)
shall be in accordance with table I, subgroup 2 herein.
Subgroup
Method
Conditions
C2
2036
Test condition E.
See 4.3.4, RθJC(max) = 15°C /W.
*
C5
3161
C6
1042
Test condition D: 6,000 cycles. The heating cycle shall be 30 seconds minimum.
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table E-IX of MIL-PRF-19500, and table II herein. Electrical measurements (end-
points) shall be in accordance with table I, subgroup 2 herein.
4.5 Methods of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows:
4.5.1 Pulse measurements. Conditions for pulse measurements shall be as specified in section 4 of MIL-STD-750.