MIL-PRF-19500/570E
TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 4 - Continued
td(off)
Turn-off delay time
2N6901
45
ns
VDD = 50 V dc
2N6903
40
ns
VDD = 100 V dc
Fall time
80
ns
tf
2N6901
VDD = 50 V dc
2N6903
VDD = 100 V dc
Subgroup 5
Safe operating area
3474
See figure 4
(SOA) test
VDS = 80 percent of rated
VDS and VDS < 200 V max
High voltage dc SOA
tp = 1 ms
Electrical measurements
See table I, subgroup 2
Single pulse unclamped
See 4.3.3; c = 0, 116
3470
inductive switching
devices
Electrical measurements
See table I, subgroup 2
Subgroups 6
Not applicable
Subgroup 7
Gate charge
3471
Condition A or B
On-state gate charge
Qg(on)
2N6901
nC
5
2N6903
5
nC
See footnote at end of table.