MIL�PRF�19500/599E
TABLE I. Group A inspection.
Limit
Inspection 1/
Unit
Symbol
Max
Min
Method
Conditions
Subgroup 1
Visual and mechanical
2071
inspection
Subgroup 2
�C/W
Thermal impedance 2/
3161
See 4.3.1.3
10
ZθJC
Breakdown voltage,
3407
Bias condition C,
V(BR)DSS
�100
V dc
drain-to-source
VGS = 0V, ID = �1 mA dc
VDS ≥ VGS,
Gate-to-source
3403
VGS(th)1
�2.0
�4.0
V dc
voltage (threshold)
ID = �0.25 mA
Gate current (forward)
3411
Bias condition C, VGS = +20V dc,
IGSSF1
�100
nA dc
VDS = 0 V dc
Gate current (reverse)
3411
Bias condition C, VGS = �20 V dc,
IGSSR1
�100
nA dc
VDS = 0 V dc
�A dc
Drain current
3413
Bias condition C, VGS = 0 V dc,
IDSS1
�25
VDS = 80 percent of rated VDS
Ω
Static drain to source
3421
Bias condition A, VGS = �10 V dc,
rDS(on)1
1.4
on-state resistance
pulsed (see 4.5.1)
Forward voltage
4011
VGS = 0 V dc, ID = rated ID1,
VSD
5.5
V
Subgroup 3
TC = TJ = +125�C
High temperature operation:
Gate current
3411
Bias condition C, VDS = 0 V dc,
IGSS2
�200
nA dc
VGS = +20V dc and �20 V dc
Drain current
3413
Bias condition C, VGS = 0 V dc,
IDSS2
�0.25
mA dc
VDS = 80 percent of rated VDS
Ω
Static drain-to-source
3421
rDS(on)2
2.3
Bias condition A, VGS = �10 V dc,
on-state resistance
See footnote at end of table.
11