MILPRF19500/599E
TABLE I. Group A inspection Continued.
Limit
Inspection 1/
Unit
Symbol
Max
Min
Method
Conditions
Subgroup 3 Continued
VDS ≥ VGS, ID = 0.25 mA
Gate-to-source voltage
3403
VGS(th)2
1.0
V dc
(threshold)
TC = TJ = 55°C
Low temperature operation:
VDS ≥ VGS, ID = 0.25 mA
Gate-to-source voltage
3403
VGS(th)3
-5.0
V dc
(threshold)
Subgroup 4
Switching time test
3472
ID = rated ID1; VGS = 10 V dc;
RG = 7.5 Ω;
VDD = 50 percent of V(BR)DSS
Turn-on delay time
td(on)
30
ns
Rise time
tr
60
ns
Turn-off delay time
td(off)
70
ns
Fall time
tf
80
ns
Subgroup 5
Single pulse unclamped
3470
See 4.3.1.2, n = 116, c = 0
EAS
inductive switching 3/
Electrical measurements
See subgroup 2 of this table
Safe operating area test
3474
VDS = 80 percent of rated V(BR)DSS,
for power MOSFETs
ID = 0.5 A, tp = 10 ms,
(see figure 5)
Electrical measurements
See subgroup 2 of this table
Subgroup 6
Not applicable
See footnote at end of table.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.