MIL�PRF�19500/599E
4.3.1.1 Gate stress test. Apply VGS = +30 V minimum for t = 250 �s minimum.
4.3.1.2 Single pulse avalanche energy (EAS). The single pulse avalanche energy capability shall be performed in
a.
Peak current (IAS)
ID1.
�10 V.
b.
Peak gate voltage (VGS)
25 ≤ RGS ≤ 200Ω.
Gate to source resistor (RGS)
c.
+25�C +10�C, �5�C.
d.
Initial case temperature
2 E AS (V BR - V DD )
2
e.
Inductance
mH minimum
( I D1 )
V BR
f.
Number of pulses to be applied
1 pulse minimum.
Supply voltage (VDD)
�25 V minimum.
g.
4.3.1.3 Thermal impedance (ZθJC measurements). The thermal impedance measurements shall be performed in
accordance with method 3161 of MIL�STD�750 using the guidelines in that method for determining IM, IH, tH, tSW,
(and VH where appropriate). Measurement delay time (tMD) = 70 �s maximum. (See figure 4 herein for thermal
4.3.2 Screening of unencapsulated die (JANHC and JANKC). Screening of JANHC and JANKC unencapsulated
die shall be in accordance with appendix G of MIL�PRF�19500. The burn-in duration for JANKC level shall follow the
JANS requirements; the JANHC level shall follow the JANTX requirements of table E�IV of MIL�PRF�19500. As a
minimum, die shall be 100 percent probed in accordance with group A.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL�PRF�19500, and as
specified herein. Alternate flow is allowed for conformance inspection in accordance with MIL�PRF�19500.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with table E�V of
MIL�PRF�19500, and table I herein. Electrical measurements (end-points) shall be in accordance with table I,
subgroup 2 herein. Delta requirements shall be in accordance with the applicable steps of table II herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E�VIA (JANS) and table E�VIB (JAN, JANTX, and JANTXV) of MIL�PRF�19500 and
herein. Electrical measurements (end-points) shall be in accordance with table I, subgroup 2 herein. Delta
requirements shall be in accordance with the applicable steps of table II herein.