MIL-PRF-19500/601K
TABLE I. Group A inspection - Continued.
Inspection 1/
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 3
TC = TJ = +125°C
High-temperature
operation:
± 200
Gate current
3411
VGS = +20 V dc and -20 V dc,
IGSS2
nA dc
bias condition C, VDS = 0
Drain current
3413
VGS = 0, bias condition C,
VDS = 100 percent of rated VDS
IDSS2
1.0
mA dc
VDS = 80 percent of rated VDS
IDSS3
0.25
mA dc
Static drain to source
3421
rDS(on)3
on-state resistance
ID = ID2
2N7261, 2N7261U, 2N7261U5
0.350
ohm
2N7262, 2N7262U, 2N7262U5
0.6
ohm
VDS ≥ VGS, ID = 1 mA dc
Gate to source
3403
VGS(TH)2
1.0
V dc
voltage (thresholds)
TC = TJ = -55°C
Low-temperature
operation:
VDS ≥ VGS, ID = 1 mA dc
Gate to source
3403
VGS(TH)3
5.0
V dc
voltage (threshold)
Subgroup 4
ID = rated ID2, VDD = 15 V, pulsed
Forward transconductance
3475
gFS
(see 4.5.1)
2N7261, 2N7261U, 2N7261U5
2N7262, 2N7262U, 2N7262U5
2.5
S
2.5
S
Switching time test
3472
ID = ID1, VGS = 12 V dc,
RG = 2.35Ω, VDD = 50 percent
of rated VDS
Turn-on delay time
td(on)
2N7261, 2N7261U, 2N7261U5
25
ns
2N7262, 2N7262U, 2N7262U5
25
ns
See footnote at end of table.
13
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business