MIL-PRF-19500/615G
TABLE I. Group A inspection - Continued.
Limits
Symbol
Unit
Inspection 1/
Method
Condition
Min
Max
Subgroup 5
Safe operating area test
3474
(high voltage)
tp = 10 ms, VDS = 80 percent of
rated V(BR)DSS
Electrical measurements
See table I, subgroup 2
Subgroup 6
Not applicable
Subgroup 7
Gate charge
3471
Condition B
On-state gate charge
Qg(on)
2N7382
45
nC
2N7383
45
nC
Gate to source charge
Qgs
2N7382
10
nC
2N7383
10
nC
Gate to drain charge
Qgd
2N7382
25
nC
2N7383
25
nC
di/dt ≤ -100 A/µs, VDD ≤ -50 V,
Reverse recovery time
3473
trr
2N7382
250
ns
2N7383
400
ns
1/
For sampling plan, see MIL-PRF-19500.
2/
This test required for the following end-point measurements only:
Group B, subgroups 3 and 4 (JANS).
Group B, subgroups 2 and 3 (JANTXV).
Group C, subgroups 2 and 6.
Group E, subgroup 1.