MIL-PRF-19500/260L
* TABLE II. Group E inspection (all quality levels) for qualification and requalification only.
Inspection
MIL-STD-750
Sampling
plan
Method
Conditions
Subgroup 1
45 devices
c=0
100 cycles, 0°C to 100°C.
Thermal shock
1056
Electrical measurements
See table I, subgroup 2 herein.
Hermetic seal
1071
Electrical measurements
See table I, subgroup 2 and table III, step 1.
Subgroup 2
22 devices
c=0
1,000 hours.
Steady-state dc blocking
1048
life
See table I, subgroup 2 and table III, steps 1 and 2.
Electrical measurements
Subgroup 4
See table E-IX of MIL-PRF-19500, group E, subgroup 4.
Thermal impedance
curves
Subgroup 5
22 devices
c=0
Barometric pressure,
1001
Hg = rated Hg (see 1.3), t = 60 s, While the 22 devices,
reduced (altitude
c = 0; test is being performed, IR shall be monitored and
operation)
shall not exceed table I limits.
N/A
1N1202A, AR
400 V dc
1N1204A, AR
600 V dc
1N1206A, AR
800 V dc
1N3671A, AR
1,000 V dc
1N3673A, AR
Subgroup 6
Subgroup 7
11