MIL-PRF-19500/286K
TABLE I. Group A inspection - Continued.
Inspection 1/
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 4
µs
Reverse recovery time
4031
Condition B, IF = 0.5 A,
trr
5
IR = 1.0 A, I(REC) = 0.25 A
Scope display
4023
Sharp and stable, n = 116; c = 0
Subgroup 5
Not applicable
Subgroup 6
Forward surge
4066
IFSM = 25 A (pk); ten surges of
8.3 ms each at 1 minute
intervals, superimposed on IO =
1A
TA = +55°C
See table I, subgroup 2
Electrical
measurements
Subgroup 7
Not applicable
For sampling plan, see MIL-PRF-19500.
1/
*
2/
This test required for the following end-point measurement only:
Group B, subgroups 2 and 3 (JAN, JANTX, and JANTXV).
Group C, subgroup 2.
Group E, subgroup 1.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business