MIL-PRF-19500/313J
4.3.3 Thermal impedance. The thermal impedance measurements shall be performed in accordance with
method 3131 of MIL-STD-750 using the guidelines in that method for determining IM, IH, tH, tMD (and VC where
appropriate). The thermal impedance limit shall comply with the thermal impedance graph in figures 7, 8, and 9 (less
than or equal to the curve value at the same tH time) or shall be less than the process determined statistical maximum
limit as outlined in method 3131 of MIL-STD-750. See table II, subgroup 4 herein.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500 and as
specified herein.
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with MIL-PRF-19500, and table I
herein.
* 4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E-VIa (JANS) of MIL-PRF-19500 and 4.4.2.1. Electrical measurements (end-
points) and delta requirements shall be in accordance with table I, subgroup 2 and 4.5.7 herein. See 4.4.2.2 for JAN,
JANTX, and JANTXV group B testing. Electrical measurements (end-points) and delta requirements for JAN,
JANTX, and JANTXV shall be after each step in 4.4.2.2 and shall be in accordance with table I, subgroup 2 and 4.5.7
herein.
*
4.4.2.1 Group B inspection (JANS), table E-VIa of MIL-PRF-19500.
Subgroup Method
Condition
VCB = 10 V dc.
B4
1037
VCB = 10 V dc; PD ≥ 100 percent of maximum rated PT (see 1.3). (NOTE: If a failure
B5
1027
occurs, resubmission shall be at the test conditions of the original sample.)
Option 1: 96 hours minimum sample size in accordance with MIL-PRF-19500, table VIa,
adjust TA or PD to achieve TJ = +275°C minimum.
Option 2: 216 hours minimum, sample size = 45, c = 0; adjust TA or PD to achieve a
TJ = +225°C minimum.
4.4.2.2 Group B inspection, (JAN, JANJ, JANTX, and JANTXV). Separate samples may be used for each step.
In the event of a lot failure, the resubmission requirements of MIL-PRF-19500 shall apply. In addition, all catastrophic
failures during CI shall be analyzed to the extent possible to identify root cause and corrective action. Whenever a
failure is identified as wafer lot or wafer processing related, the entire wafer lot and related devices assembled from
the wafer lot shall be rejected unless an appropriate determined corrective action to eliminate the failures mode has
been implemented and the devices from the wafer lot are screened to eliminate the failure mode.
Method
Condition
Step
Steady-state life: 1,000 hours minimum, VCB = 10 V dc, power shall be applied to achieve
1
1026
TJ = +150°C minimum using a minimum of PD = 75 percent of maximum rated PT as defined
in 1.3. n = 45 devices, c = 0. The sample size may be increased and the test time
decreased as long as the devices are stressed for a total of 45,000 device hours minimum,
and the actual time of test is at least 340 hours.
Blocking life, TA = +150°C, VCB = 80 percent of rated voltage, 48 hours minimum.
2
1048
n = 45 devices, c = 0.
High-temperature life (non-operating), t = 340 hours, TA = +200°C. n = 22, c = 0.
3
1032
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.