MIL-PRF-19500/357M
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 2 - Continued
Collector to base cutoff
3036
100
nA dc
Bias condition D, VCB = 100 V dc
ICBO2
current
Emitter to base cutoff current
3061
50
nA dc
Bias condition D, VEB = 3 V dc
IEBO2
µA dc
Collector to emitter cutoff
3041
10
Bias condition D, VCE = 100 V dc
ICEO
current
Forward-current transfer ratio
3076
VCE = 10 V dc, IC = 0.1 mA dc pulsed
hFE1
(see 4.5.1)
2N3634, 2N3634L, UB, UBN
25
2N3635, 2N3635L, UB, UBN
2N3636, 2N3636L, UB, UBN
55
2N3637, 2N3637L, UB, UBN
Forward-current transfer ratio
3076
VCE = 10 V dc, IC = 1.0 mA dc pulsed
hFE2
(see 4.5.1)
2N3634, 2N3634L, UB, UBN
45
2N3635, 2N3635L, UB, UBN
2N3636, 2N3636L, UB, UBN
90
2N3637, 2N3637L, UB, UBN
Forward-current transfer ratio
3076
VCE = 10 V dc, IC = 10 mA dc pulsed
hFE3
(see 4.5.1)
2N3634, 2N3634L, UB, UBN
50
2N3635, 2N3635L, UB, UBN
2N3636, 2N3636L, UB, UBN
100
2N3637, 2N3637L, UB, UBN
Forward-current transfer ratio
3076
VCE = 10 V dc, IC = 50 mA dc pulsed
hFE4
(see 4.5.1)
2N3634, 2N3634L, UB, UBN
50
150
2N3635, 2N3635L, UB, UBN
2N3636, 2N3636L, UB, UBN
100
300
2N3637, 2N3637L, UB, UBN
Forward-current transfer ratio
3076
VCE = 10 V dc, IC = 150 mA dc pulsed
hFE5
(see 4.5.1)
2N3634, 2N3634L, UB, UBN
30
2N3635, 2N3635L, UB, UBN
2N3636, 2N3636L, UB, UBN
60
2N3637, 2N3637L, UB, UBN
See footnotes at end of table.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.