MIL-PRF-19500/382J
4.4.2.3 Group B sample selection. Samples selected from group B inspection shall meet all of the following
requirements:
a. For JAN, JANTX, and JANTXV samples shall be selected randomly from a minimum of three wafers (or from
each wafer in the lot) from each wafer lot. For JANS, samples shall be selected from each inspection lot.
See MIL-PRF-19500.
b. Shall be chosen from an inspection lot that has been submitted to and passed table I, subgroup 2,
conformance inspection. When the final lead finish is solder or any plating prone to oxidation at high
temperature, the samples for life test (subgroups B4 and B5 for JANS, and group B for JAN, JANTX, and
JANTXV) may be pulled prior to the application of final lead finish.
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E-VII of MIL-PRF-19500, and 4.4.3.1 (JANS), and 4.4.3.2 (JAN, JANTX, and
JANTXV) herein for group C testing. Electrical measurements (end-points) and delta requirements shall be in
4.4.3.1 Group C inspection, table E-VII (JANS) of MIL-PRF-19500.
Subgroup
Method
Condition
C2
2036
Test condition E (not applicable to UB).
C5
3131
figures 6 and 7.
C6
1026
Steady-state life: 1,000 hours, VCB = 10 V dc; power shall be applied to achieve
TJ = +150°C minimum and a minimum of PD = 75 percent of maximum rated PT
as defined in 1.3 n = 45, c = 0. The sample size may be increased and the test time
decreased as long as the devices are stressed for a total of 45,000 device hours
minimum, and the actual time of test is at least 340 hours.
4.4.3.2 Group C inspection, table E-VII (JAN, JANTX, and JANTXV) of MIL-PRF-19500.
Subgroup
Method
Condition
C2
2036
Test condition E (not applicable to UB).
C5
3131
figures 6 and 7.
C6
1037
Not applicable.
4.4.3.3 Group C sample selection. Samples for subgroups in group C shall be chosen at random from any
inspection lot containing the intended package type and lead finish procured to the same specification which is
submitted to and passes table I tests herein for conformance inspection. When the final lead finish is solder or any
plating prone to oxidation at high temperature, the samples for C6 life test may be pulled prior to the application of
final lead finish. Testing of a subgroup using a single device type enclosed in the intended package type shall be
considered as complying with the requirements for that subgroup.